FTD110DB-XXR3 Series Installation & Operation Manual
www.ot-systems.com 11
RS232 Data communication connection diagram:
Transmitter End Receiver End
User’s Equipment
DATA PORT
(7-PIN)
DATA PORT
(7-PIN)
User’s Equipment
1 N/A
1 N/A
2 N/A
2 N/A
3 N/A
3 N/A
4 N/A
4 N/A
TX
5 IN
5 IN
TX
RX
6 OUT
6 OUT
RX
Sig. COM
7 Sig. COM
7 Sig. COM
Sig. COM
Fig. 4.3.3 Connector Pin Assignments for RS232 data format at Data port
4.3 Dip switch setting procedures
The only setup procedure is to select the appropriate line terminations and data
transmission formats. Selections must be made by setting the dip switches (Fig. 4.8) through the
access on the front panel.
(a) Dip switches on FTD110DB-XXR3 Series Standalone unit
(b) Dip switches on FTD110DB-XXR3 Series Card Module
Fig. 4.4 Location of Dip Switches